Blood Glucose Monitoring SystemOwner’s Manual
9Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s ManualKey Functions of the MeterSetting Up the Prodigy PocketTM Me
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual10Control Solution Test SymbolShows that you are in Con
11Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s Manual Key Functions of the Test StripThe Prodigy PocketTM Meter
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual12 • Store test strip packages in a cool, dry place b
13Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s ManualThe Prodigy PocketTM Meter has the date, time and unit of m
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual14STEP 5: Set the DatePress and release the “M” button
15Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s ManualSTEP 8: Unit of Measurement Press and release the “M” butto
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual16Control Solution TestingAbout Prodigy® control soluti
17Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s ManualImportant Control Solution Test Information• Use only Prod
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual18Performing a Control Solution TestStart with the mete
1Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s ManualProdigy PocketTM MeterDear Prodigy® Owner:Thank you for choo
19Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s ManualSTEP 3: Apply Control SolutionShake the control solution bo
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual20STEP 4 : Check if the Test Result is in Range.After s
21Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s ManualPreparing the Lancing DeviceSTEP 1: Remove the cap by twist
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual22Alternative Site Testing (AST)When you want to obtain
23Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s Manual• Sites other Than Your Fingertip Please refer to the “Abo
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual24Performing a Blood Glucose TestSTEP 1: Insert the Tes
25Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s ManualCaution: DO NOT: • Smear or scrape the blood onto the
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual26The Prodigy PocketTM stores the 120 most recent blood
27Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s ManualSTEP 2: Recalling Average Test ResultsThe 7-day average is
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual28STEP 3: Recalling Individual Test ResultsAfter the 28
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual2Read this before using your Prodigy PocketTM Meter.The
29Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s ManualTest Results in memory can be transmitted to your personal
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual30MaintenanceThe Prodigy PocketTM does not require spec
31Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s ManualBattery ReplacementTo replace the battery, make sure the me
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual32Special messages and Error messages help to identify
33Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s Manual Message What it means ActionAppears when th
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual34Battery exhausted. Replace the battery.Battery incor
35Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s ManualvThe test does not start after applying the sample.Probabl
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual36Information about Your Prodigy PocketTM MeterCompari
37Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s ManualYou may still have a variation from the result because bloo
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual38SpecificationsDimensions: 3.54 in. (L) x 1.38 in.
3Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s ManualImportant Safety Instructions ...
39Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s ManualPerformance Characteristics• Accuracy: ±15mg/dL when gluco
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual40Time of day Plasma glucose range Your target for
41Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s ManualMeterREF 50300 - K (Black)REF 50301 - P (Pink)REF 50302 -
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual42
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual4Severe dehydration and excessive water loss may cause
5Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s ManualThere are important limitations to AST. Please consult your
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual6Use AST only: v Two hours or more after your last me
7Diagnostic Devices, Inc. 1.800.243.2636Prodigy Meter Owner’s ManualIntended UseThe system is intended for use outside the body
Diagnostic Devices, Inc. www.prodigymeter.comProdigy Meter Owner’s Manual8The Prodigy PocketTM Meter is available as a meter onl